AC Size by Room Type
ENERGY STAR’s room AC chart and adjustments (8 ft ceilings). Unit size: the smallest chart size within 90–115% of the need (ENERGY STAR’s recommended range for single-speed central systems, which this site also uses for room units). For glass rooms, garages, mobile homes and commercial spaces, see their sections below.
| Buy a unit of about | — |
| Chart band | — |
AC size by room type at a glance
Typical sizes for the usual floor area of each space. The sections below explain each one; use the calculator for your own room.
| Space | Typical area | Typical size |
|---|---|---|
| Rooms in a home | ||
| Bedroom | 140 sq ft | 5,000 BTU |
| Living room | 250 sq ft | 7,000 BTU |
| Kitchen | 120 sq ft | 9,000 BTU |
| Home office | 120 sq ft | 5,000 BTU |
| Study or small room | 90 sq ft | 5,000 BTU |
| Attic room or loft | 200 sq ft | 6,000 BTU |
| Basement | 600 sq ft | 12,000 BTU |
| Glass rooms | ||
| Sunroom or conservatory | 200 sq ft | 12,000 BTU |
| Garages and manufactured homes | ||
| Garage or garage gym | 440 sq ft | 14,000 BTU |
| Mobile or manufactured home | 900 sq ft | see the certificate |
| Commercial and specialist spaces | ||
| Server room or IT closet | 120 sq ft | 3,412 BTU/h per kW of equipment |
| Restaurant dining area | — | use the commercial calculator |
| Retail shop | — | use the commercial calculator |
| Salon | — | use the commercial calculator |
| Classroom or training room | — | use the commercial calculator |
| Gym or fitness studio | — | use the commercial calculator |
Bedroom
A typical bedroom of about 140 sq ft: ENERGY STAR’s chart gives 5,000 BTU for 100–150 sq ft, so a 5,000 BTU unit.
Bedrooms are where oversizing hurts most. An oversized unit cools the room fast, shuts off, and leaves it cold but clammy in the small hours; a right-sized one runs longer, quieter cycles. Check the unit’s noise rating as well as its capacity.
Living room
A 250 sq ft living room that usually holds four people: ENERGY STAR’s chart gives 6,000 BTU for 150–250 sq ft (+1,200 BTU for 4 people): about 7,200 BTU, so a 7,000 BTU unit (97%).
Size for the number of people who are normally there, not the party you host twice a year. In an open plan, the kitchen and dining area share the air, so size the whole open space and add the kitchen allowance.
Kitchen
A 120 sq ft kitchen: ENERGY STAR’s chart gives 5,000 BTU for 100–150 sq ft (+4,000 BTU for a kitchen): about 9,000 BTU, so a 9,000 BTU unit.
Cooking adds a lot of heat while the hob and oven are on, which is why ENERGY STAR adds 4,000 BTU for a kitchen. Run the range hood while cooking: it removes heat and grease at the source. Keep the indoor unit out of the cooker’s airflow so grease does not coat its coil.
Home office
A 120 sq ft home office: ENERGY STAR’s chart gives 5,000 BTU for 100–150 sq ft, so a 5,000 BTU unit.
Computers and monitors turn the electricity they use into heat: every watt adds 3.412 BTU per hour. A 300 W desktop and two monitors running all day add about 1,000 BTU/h, so a busy office can need the next size up. ENERGY STAR’s chart does not include equipment, so add it yourself.
Study or small room
A 90 sq ft study: ENERGY STAR’s chart gives 5,000 BTU for 100–150 sq ft, so a 5,000 BTU unit (the chart starts at 100 sq ft, and 5,000 BTU is the smallest common size).
Small units are sized for small rooms, so resist the next size up. If the door stays open to the rest of the house, the unit ends up cooling the hallway too, and a larger whole-home answer applies.
Attic room or loft
A 200 sq ft attic room: ENERGY STAR’s chart gives 6,000 BTU for 150–250 sq ft (+10% for sun): about 6,600 BTU, so a 6,000 BTU unit (91%), using ENERGY STAR’s +10% very-sunny adjustment for a room right under the roof (our application of the chart).
Rooms under the roof take heat through the ceiling and the sloped walls. Insulating and ventilating the roof space usually does more than a bigger unit, and if the room still runs hot, use the tonnage calculator with “top floor” selected.
Basement
A 600 sq ft finished basement: ENERGY STAR’s chart gives 14,000 BTU for 550–700 sq ft (−10% for shade): about 12,600 BTU, so a 12,000 BTU unit (95%), using ENERGY STAR’s −10% shaded adjustment because walls below ground stay cool (our application of the chart).
Basements need less cooling than rooms above ground but can be humid. If it feels damp rather than hot, a dehumidifier may be what you need, and an oversized AC makes dampness worse because it runs in short bursts.
Sunroom or conservatory
A 200 sq ft sunroom: ENERGY STAR’s chart with its very-sunny adjustment gives about 6,600 BTU, but the chart assumes a normal room with ordinary walls and windows. A room that is mostly glass gains far more. Our calculator, set for six large windows, a 9 ft ceiling, full sun, a roof and average-to-poor insulation, estimates about 12,900 BTU/h, so plan on a 12,000 BTU unit (93%), usually a ductless mini-split. Treat the chart as the floor and this site’s planning estimate as a guide, not an exact load.
Conservatory: the same applies to an all-glass conservatory. A 180 sq ft one with a glass roof, set for eight large windows and a 10 ft ceiling (otherwise the same settings), estimates about 14,700 BTU/h. Shade first: blinds, solar-control glass or film on the roof panels cut the load.
Garage or garage gym
A two-car garage of about 440 sq ft: ENERGY STAR’s chart gives 10,000 BTU for an ordinary insulated room. Most garages are not insulated and the big door leaks, so our calculator, set for poor insulation, full sun and a 9 ft ceiling, estimates about 13,500 BTU/h.
Garage gym: people exercising give off much more heat than people sitting, and equipment adds more. With an extra 1,200 BTU/h allowance for two people training (our assumption), the estimate is about 14,700 BTU/h, so a 14,000 BTU mini-split (95%). A fan moving air over you does a lot for comfort in a gym.
Insulating the garage door and sealing its edges is the cheapest upgrade. A ductless mini-split suits most garages; a window unit needs a suitable window and an outlet.
Mobile or manufactured home
Every manufactured home built to the federal HUD Code carries a Comfort Cooling Certificate on an interior wall (24 CFR 3280.511). It says whether the home is suitable for central air conditioning and gives the maximum certified central AC capacity; the rule also says the unit should be sized to the calculated cooling load for the home’s location and orientation. Start there.
This site’s planning estimate puts a 900 sq ft home at about 19,300 BTU/h in a moderate climate, which is 1.5 tons inside ENERGY STAR’s sizing range. Older homes with little insulation or leaky under-floor ducts can need more; use the tonnage calculator with “poor insulation” and “top floor” to see how much. Ductless mini-splits avoid the under-floor ducts altogether.
Server room or IT closet
Size a server room on its equipment, not its floor area. Electronics turn essentially all the power they draw into heat: BTU/h = watts × 3.412. One 5 kW rack gives off about 17,060 BTU/h (1.4 tons) whatever the room size, plus the room’s own small gain. Use the measured UPS output if you have it.
The load runs around the clock, all year, so ordinary comfort ACs are a poor fit: look for equipment rated for continuous duty and for cooling when it is cold outside. Many rooms use two units so one can fail without the room overheating.
Restaurant dining area
The load in a restaurant dining area is dominated by diners, lighting and heat from the kitchen pass. Seat count drives the size, so enter your realistic full-service count. Size the dining room only: commercial kitchens need hood and make-up-air design by a mechanical engineer.
ENERGY STAR’s room chart is written for homes, so we do not apply it here. Use the commercial tonnage calculator with your floor area, people and equipment, and have a contractor run a commercial load calculation before buying.
Retail shop
The load in a retail shop is dominated by customers, display lighting and the entrance door. A door that opens all day lets in outdoor air constantly; an air curtain or vestibule reduces that.
ENERGY STAR’s room chart is written for homes, so we do not apply it here. Use the commercial tonnage calculator with your floor area, people and equipment, and have a contractor run a commercial load calculation before buying.
Salon
The load in a salon is dominated by hair dryers, styling tools and staff and clients. Dryers are heaters pointed at people, so count their wattage as heat (watts × 3.412 = BTU/h) and plan ventilation for chemical smells.
ENERGY STAR’s room chart is written for homes, so we do not apply it here. Use the commercial tonnage calculator with your floor area, people and equipment, and have a contractor run a commercial load calculation before buying.
Classroom or training room
The load in a classroom or training room is dominated by people: a full room of students sets the size. Fresh-air ventilation for that many people is a requirement in its own right and adds to the load.
ENERGY STAR’s room chart is written for homes, so we do not apply it here. Use the commercial tonnage calculator with your floor area, people and equipment, and have a contractor run a commercial load calculation before buying.
Gym or fitness studio
The load in a gym or fitness studio is dominated by people exercising, who give off more heat than people sitting, plus equipment.
ENERGY STAR’s room chart is written for homes, so we do not apply it here. Use the commercial tonnage calculator with your floor area, people and equipment, and have a contractor run a commercial load calculation before buying.
India: rooms are cooled with split ACs sized in tons; switch the tonnage calculator to India mode for a room-by-room answer.
FAQ
What size AC do I need for a bedroom?
For a typical 140 sq ft bedroom, ENERGY STAR’s chart gives 5,000 BTU. A 150–250 sq ft bedroom needs 6,000 BTU and a 250–300 sq ft one 7,000. Add 10% for a very sunny room.
What size AC do I need for a kitchen?
Use ENERGY STAR’s chart for the floor area and add 4,000 BTU. A 120 sq ft kitchen comes to about 9,000 BTU (5,000 + 4,000).
What size air conditioner do I need for a sunroom?
ENERGY STAR’s room chart is only a floor for a mostly-glass room. For a 200 sq ft sunroom it gives about 6,600 BTU with the very-sunny adjustment; our calculator, set for six large windows and full sun, estimates about 12,900 BTU/h.
What size AC do I need for a garage gym?
For a 440 sq ft two-car garage, our calculator estimates about 13,500 BTU/h uninsulated, and about 14,700 BTU/h with two people training. ENERGY STAR’s chart gives 10,000 BTU, but it assumes an insulated room.
What size AC do I need for a mobile home?
Check the Comfort Cooling Certificate on an interior wall of the home: federal rules (24 CFR 3280.511) require it to state whether the home suits central air and the maximum certified capacity. On this site’s planning estimate, a 900 sq ft home in a moderate climate needs about 19,300 BTU/h (1.5 tons); older, poorly insulated homes need more.
How much cooling does a server room need?
About 3,412 BTU/h for every kilowatt of IT load, because the equipment turns its power into heat. A 5 kW rack needs about 17,060 BTU/h (1.4 tons) plus the room’s own gain.
Why does room type change the AC size?
Two rooms of the same size can need very different cooling. People, appliances and electronics add heat; glass and uninsulated walls let it in. ENERGY STAR’s chart covers ordinary rooms and adds allowances for sun, people and kitchens; glass rooms, garages and commercial spaces need more than the chart shows.
Sources
Official sources only, checked October 2026.
- ENERGY STAR: Room air conditioners — sizing chart — capacity by room area (8 ft ceilings) and adjustments: −10% heavily shaded, +10% very sunny, +600 BTU per person beyond two, +4,000 BTU for a kitchen
- 24 CFR 3280.511 — Comfort cooling certificate (Manufactured Home Construction and Safety Standards, eCFR) — certificate on an interior wall; maximum certified central AC capacity; size to the calculated cooling load
Updated 6 November 2026