Furnace Size Calculator
Furnace size comes from heat loss at your county’s coldest design temperature, not a flat BTU-per-square-foot rule. Pick your county, describe the house, and get the output range ENERGY STAR’s design rules allow.
Pick your county to fill the 99% heating design temperature from EPA’s ENERGY STAR reference guide, or type your own. Picking your county also sets its 2021 IECC climate zone (see the climate zone map).
Assumptions used (editable)
| Furnace output range | — |
| Suggested input size | — |
| Its output at this AFUE | — |
| Heat loss per sq ft | — |
Where the heat goes
| Part of the house | Heat loss at design | Share |
|---|
Choosing the furnace size
ENERGY STAR’s HVAC design rules require the furnace’s output capacity to be 100–140% of the design heat loss when it only heats. When the same air handler also serves central air conditioning, 100–140% is still the recommendation, though up to 400% is allowed because the blower is often sized for cooling airflow. For two-stage and modulating furnaces, use the maximum output.
Input vs output: furnaces are sold by gas input (for example 60,000 Btu/h). This calculator estimates output as input × AFUE, but AFUE is a seasonal rating, so read the actual output capacity on the furnace’s rating plate or spec sheet before deciding. The suggested input sizes are the gas input ratings in Lennox’s current model list, where the model code is not always the rating: a code 045 furnace is rated 44,000 Btu/h input, 070 is 66,000, 090 is 88,000 and 135 is 132,000.
Efficiency minimum: non-weatherized gas furnaces must be at least 80% AFUE today, rising to 95% AFUE for furnaces made on or after December 18, 2028 under 10 CFR 430.32(e). Gas utility groups petitioned DOE in 2026 to delay that date; DOE had not decided as of October 2026.
How the heat loss is calculated
Heat loss at the design temperature = (sum of each surface’s area × its U-factor + air leakage) × (70°F indoors − the outdoor design temperature). The 70°F indoor and the 99% outdoor design temperature are the conditions ENERGY STAR requires for HVAC design.
- Design temperature: the county value from EPA’s ENERGY STAR Design Temperature Limit Reference Guide (2019 edition), which EPA compiled from ASHRAE and ACCA Manual J weather data. Where several weather stations fall within 40 miles of a county’s centre, EPA uses the coldest — so the value is on the safe side. A local jurisdiction’s own design temperature takes precedence.
- Surfaces: the home is treated as a square box of the given floor area and stories, with windows as a share of wall area.
- U-factors: the “new, 2021 IECC” option uses the code’s maximum U-factors for your climate zone (marine zone 4C uses the zone 5 column, as the code table does). The other options are labelled assumptions, because no official values exist for existing homes; open “Assumptions used” to see or change them.
- Air leakage: blower-door ACH50 converted to natural air changes with LBNL’s method (÷ about 19, adjusted for stories), then × 1.5 for design-day conditions (New York State Clean Heat guidance). For the existing-home options the result is capped at 0.7 air changes per hour, the same guidance’s limit for existing buildings unless test data justify more. The 2021 IECC limit is 3.0 ACH50 in zones 3–8 and 5.0 in zones 1–2.
- Floor: floors over a crawlspace or unheated basement are taken to lose heat to outdoor temperature (conservative); slabs at half that rate (an assumption, since the ground is warmer than the air on a design day).
Not included: duct losses, internal gains and room-by-room effects. This is a whole-house planning estimate, not an ACCA Manual J calculation, which a contractor should run before buying.
FAQ
What size furnace do I need for a 2,000 sq ft house?
It depends on your winter design temperature and how well the house is insulated and sealed, not just its size. A typical 1990s–2000s 2,000 sq ft home near Chicago (design temperature −3°F) loses roughly 38,000 Btu/h, so a furnace with 38,000–54,000 Btu/h of output fits; a new home built to the 2021 code needs about 22,000 Btu/h.
Is a bigger furnace better?
No. ENERGY STAR caps a heating-only furnace at 140% of the design heat loss. DOE’s Building America Solution Center notes that oversized heating equipment cycles on and off more, with less even comfort.
What is the difference between furnace input and output?
Input is the gas the furnace burns, and the number it is usually sold by. Output is the heat delivered to the house; this calculator estimates it as input × AFUE. Size the furnace on output, and check the actual output on the spec sheet.
What is a design temperature?
The outdoor temperature a heating system is sized for: the 99% value is exceeded (warmer) 99% of the hours in a typical year. The calculator fills it from EPA’s ENERGY STAR county reference guide.
What AFUE do furnaces need to have?
At least 80% AFUE for non-weatherized gas furnaces today, rising to 95% for furnaces made on or after December 18, 2028 (10 CFR 430.32). A delay petition was pending with DOE in 2026.
Sources
Official sources only, checked October 2026.
- ENERGY STAR Design Temperature Limit Reference Guide, 2019 Edition (U.S. EPA) — 99% heating and 1% cooling design temperatures and HDD/CDD ratio by county; EPA compiled them from ASHRAE 2017 Handbook and ACCA Manual J 8th Ed. design conditions
- ENERGY STAR National HVAC Design Report, Rev. 13 (U.S. EPA) — indoor design 70°F heating / 75°F cooling (Item 3.2); furnace capacity 100–140% of heat loss (Item 4.21); heat pump cooling sizing limits (Item 4.15)
- 2021 IECC Table R402.1.2 maximum assembly U-factors and R402.4.1.2 air leakage, as reproduced by the ICC — U-factors for windows, ceilings, walls and floors by climate zone; 5.0 ACH50 in zones 0–2, 3.0 ACH50 in zones 3–8
- U.S. DOE: How DOE Efficient New Homes Can Leverage High-Performance Windows (2025) — 2021 IECC envelope U-factors, zones 2–6 (cross-check)
- Sherman (1987), Energy and Buildings 10:81–86 (LBNL): Estimation of Infiltration from Leakage and Climate Indicators — natural air changes ≈ ACH50 ÷ N, US average N ≈ 19, with height factors for 2 and 3 stories
- NYS Clean Heat: Infiltration Guidance for Buildings at Design Conditions — 1.5× multiplier from average to heating design-day infiltration for low-rise homes
- 10 CFR 430.32 — federal energy conservation standards (eCFR)
- Lennox Model Number Identification (Current Product), March 2025 — furnace gas input rating for each model code (030–135)
- Federal Register 2026-08145: petition to delay the furnace standard
- PNNL-33270: Guide to Determining Climate Zones by County: Building America and IECC 2021 Updates — official county-to-climate-zone list
actonnagecalc.com is not affiliated with, or endorsed by, the U.S. EPA, ENERGY STAR®, DOE or the ICC. Their publications are cited as sources.
Updated 6 November 2026