Heat Pump Size Calculator
A heat pump is sized from the cooling load, then checked against your county’s winter design temperature. See how much of the heat loss it covers, where the balance point falls, and how much backup heat you need.
Pick your county to fill the 99% heating design temperature from EPA’s ENERGY STAR reference guide, or type your own. Picking your county also sets its 2021 IECC climate zone (see the climate zone map).
Assumptions used (editable)
Filled with this site’s planning estimate from floor area and summer climate (a different, simpler estimate from the room-by-room whole-house calculator); replace it with a Manual J figure if you have one.
| Cooling load | — |
| Heat loss at design temp | — |
| Heat pump output at design | — |
| Balance point | — |
| Backup heat at design | — |
Heat output vs heat loss
| Outdoor temp | Home’s heat loss | Heat pump output | Backup needed |
|---|
Heat pump output is a straight line between its 47°F capacity and its low-temperature capacity. Real equipment data (the manufacturer’s extended performance tables) should replace these figures before you buy.
How the size is chosen
The size starts from the cooling load, within ENERGY STAR’s cooling sizing limits: recommended 90–115% of the cooling load for single-speed, 90–120% for two-speed and 90–130% for variable-speed compressors (allowed up to 130%, 140% and 160%). These percentages use the nominal size (tons × 12,000 Btu/h); ENERGY STAR checks the manufacturer’s capacity at design conditions, so confirm with the expanded performance data. The calculator picks the smallest size in the recommended range that covers your design-day heat loss. If none does and your county is heating-dominated, it steps up to the allowed limit to reduce backup heat; otherwise it stays in the recommended range and shows the backup needed.
In heating-dominated dry climates — a heating-to-cooling degree-day ratio of 2.0 or more (shown for your county) and a cooling load that is at least 95% sensible — ENERGY STAR allows heat pump cooling capacity of 90–100% of the load plus 15,000 Btu/h, which lets you size up for winter. The calculator shows when your county may qualify.
The balance point is the outdoor temperature where the heat pump’s output equals the home’s heat loss. Below it, backup heat (electric strips or a furnace) makes up the difference. DOE’s Building America guidance describes sizing choices from “size to cooling” to “size to the full heating load”; bigger sizes cut backup use but risk short-cycling in summer.
Cold-climate heat pumps: ENERGY STAR requires their capacity at 5°F to be at least 70% of their capacity at 47°F, which is the default here. The “standard heat pump” option assumes 60% at 17°F — an assumption, so enter your unit’s real figures when you have them. Heating capacity at 47°F is assumed equal to the nominal cooling size unless you enter it.
How the heat loss is calculated
Heat loss at the design temperature = (sum of each surface’s area × its U-factor + air leakage) × (70°F indoors − the outdoor design temperature). The 70°F indoor and the 99% outdoor design temperature are the conditions ENERGY STAR requires for HVAC design.
- Design temperature: the county value from EPA’s ENERGY STAR Design Temperature Limit Reference Guide (2019 edition), which EPA compiled from ASHRAE and ACCA Manual J weather data. Where several weather stations fall within 40 miles of a county’s centre, EPA uses the coldest — so the value is on the safe side. A local jurisdiction’s own design temperature takes precedence.
- Surfaces: the home is treated as a square box of the given floor area and stories, with windows as a share of wall area.
- U-factors: the “new, 2021 IECC” option uses the code’s maximum U-factors for your climate zone (marine zone 4C uses the zone 5 column, as the code table does). The other options are labelled assumptions, because no official values exist for existing homes; open “Assumptions used” to see or change them.
- Air leakage: blower-door ACH50 converted to natural air changes with LBNL’s method (÷ about 19, adjusted for stories), then × 1.5 for design-day conditions (New York State Clean Heat guidance). For the existing-home options the result is capped at 0.7 air changes per hour, the same guidance’s limit for existing buildings unless test data justify more. The 2021 IECC limit is 3.0 ACH50 in zones 3–8 and 5.0 in zones 1–2.
- Floor: floors over a crawlspace or unheated basement are taken to lose heat to outdoor temperature (conservative); slabs at half that rate (an assumption, since the ground is warmer than the air on a design day).
Not included: duct losses, internal gains and room-by-room effects. This is a whole-house planning estimate, not an ACCA Manual J calculation, which a contractor should run before buying.
FAQ
Should a heat pump be sized for heating or cooling?
Start from the cooling load, within ENERGY STAR’s cooling limits, then check how much of the winter heat loss it covers. In cold, heating-dominated places a larger or cold-climate unit covers more of the winter, and DOE’s Building America guidance describes sizing all the way to the heating load with variable-speed equipment.
What is a heat pump balance point?
The outdoor temperature where the heat pump’s output equals the house’s heat loss. Colder than that, backup heat runs to make up the gap. A lower balance point means less backup heat.
What makes a heat pump “cold-climate”?
Under ENERGY STAR, its heating capacity at 5°F must be at least 70% of its capacity at 47°F, with a COP of at least 1.75 at 5°F, plus an HSPF2 of 8.1 or more (8.5 for ductless).
How much backup heat do I need?
Enough to cover the gap between the heat loss and the heat pump’s output at your design temperature. The calculator shows it in Btu/h and kW of electric strip heat. Sizing strips to carry the whole house in case the heat pump fails is a separate decision.
Where does the design temperature come from?
From EPA’s ENERGY STAR Design Temperature Limit Reference Guide, which lists a 99% heating design temperature for every US county.
Sources
Official sources only, checked October 2026.
- ENERGY STAR Design Temperature Limit Reference Guide, 2019 Edition (U.S. EPA) — 99% heating and 1% cooling design temperatures and HDD/CDD ratio by county; EPA compiled them from ASHRAE 2017 Handbook and ACCA Manual J 8th Ed. design conditions
- ENERGY STAR National HVAC Design Report, Rev. 13 (U.S. EPA) — indoor design 70°F heating / 75°F cooling (Item 3.2); furnace capacity 100–140% of heat loss (Item 4.21); heat pump cooling sizing limits (Item 4.15)
- ENERGY STAR air-source heat pump key product criteria — cold-climate heat pumps: capacity at 5°F at least 70% of capacity at 47°F; COP ≥ 1.75 at 5°F
- DOE Building America Solution Center: Cold Climate Heat Pump Sizing and Selection — sizing approaches, balance point, use manufacturer extended data at the design temperature
- 2021 IECC Table R402.1.2 maximum assembly U-factors and R402.4.1.2 air leakage, as reproduced by the ICC — U-factors for windows, ceilings, walls and floors by climate zone; 5.0 ACH50 in zones 0–2, 3.0 ACH50 in zones 3–8
- U.S. DOE: How DOE Efficient New Homes Can Leverage High-Performance Windows (2025) — 2021 IECC envelope U-factors, zones 2–6 (cross-check)
- Sherman (1987), Energy and Buildings 10:81–86 (LBNL): Estimation of Infiltration from Leakage and Climate Indicators — natural air changes ≈ ACH50 ÷ N, US average N ≈ 19, with height factors for 2 and 3 stories
- NYS Clean Heat: Infiltration Guidance for Buildings at Design Conditions — 1.5× multiplier from average to heating design-day infiltration for low-rise homes
- PNNL-33270: Guide to Determining Climate Zone by County (2021 IECC) — official county-to-climate-zone list
actonnagecalc.com is not affiliated with, or endorsed by, the U.S. EPA, ENERGY STAR®, DOE or the ICC. Their publications are cited as sources.
Updated 6 November 2026