What Size AC for 200 Sq Ft?
ENERGY STAR’s room AC chart and its adjustments: −10% for heavy shade, +10% for a very sunny room, +600 BTU for each person beyond two, +4,000 BTU for a kitchen. The chart assumes 8 ft ceilings. Size to look for: the smallest chart size within 90–115% of the need (ENERGY STAR’s recommended range for single-speed central systems, which this site also uses for room units).
| Size to look for | — |
| Chart band | — |
| Your unit | — |
5,000 or 6,000 BTU?
ENERGY STAR’s room AC chart splits small rooms at 150 sq ft: 5,000 BTU up to 150, 6,000 BTU from 150 to 250. A 200 sq ft room (10 × 20 ft, or about 14 ft square) sits in the 6,000 band. Two corrections can move it: add 10% for a very sunny room, take 10% off for one that is heavily shaded.
At this size the chart and our climate model agree. The model’s cooling load for a 200 sq ft space runs from 3,600 BTU/h in the cool North to 5,600 BTU/h in the hottest climates, and 6,000 BTU covers all of it.
| Summer climate | Example cities (cooling degree days) | Model load (BTU/h) | ENERGY STAR chart | Suggested size (the smallest chart size within 90–115% of the need: chart or model load, whichever is larger) |
|---|---|---|---|---|
| Hot | Miami, FL (4,656) | 5,600 | 6,000 BTU | 6,000 BTU (100%) |
| Moderate | Charlotte, NC (1,769) | 4,400 | 6,000 BTU | 6,000 BTU (100%) |
| Cool | Minneapolis, MN (830) | 3,600 | 6,000 BTU | 6,000 BTU (100%) |
Model load: the site’s whole-home model for a 200 sq ft space (8 ft ceilings, average insulation and sun). ENERGY STAR’s chart has no climate factor. Cooling degree days: NOAA 1991–2020.
What the certified 5,000 and 6,000 BTU units look like
ENERGY STAR lists 21 certified window units around 5,000 BTU and 30 around 6,000–7,000. These are the lightest room units: 30–42 lb at 5,000 BTU, so one person can usually lift one into a window.
| Size (BTU/h) | Certified window models | On 115 V | CEER | At May 2026 minimum | Weight (lb) | Saddle-mount | Listed kWh/yr (avg) |
|---|---|---|---|---|---|---|---|
| 5,000 (5,000–5,999) | 21 | 21 of 21 | 13.1–14.4 | 21 | 30–42 | 9 | 267 |
| 6,000 (6,000–7,499) | 30 | 30 of 30 | 13.7–16 | 30 | 32–62 | 12 | 317 |
ENERGY STAR certified window units, retrieved 2026-11-05. Minimum CEER for units made from May 26, 2026 from 10 CFR 430.32(b)(2), checked per product class.
Two things stand out. Every certified unit at these sizes already meets the CEER minimum that applies to units made from May 26, 2026 (13.1 below 6,000 BTU, 13.7 from 6,000 to 7,900). And all 530 certified window units in ENERGY STAR’s list report a variable-speed compressor, which lets a small unit slow down instead of switching on and off all night.
9 of the 21 certified 5,000 BTU units are saddle-mount designs that straddle the window, leaving most of the window glass clear.
Worked example: a sunny bedroom in Massachusetts
A 200 sq ft bedroom with a south-west window, used by two people. The chart gives 6,000 BTU; the sunny-room correction adds 10%, so the room needs 6,600 BTU. The smallest chart size within 90–115% of that is 6,000 BTU (91%), the size the tool above suggests.
Running cost: at 500 hours a year at full output (a labelled assumption for a New England summer) and the 14.2 CEER average of certified units this size, it uses about 211 kWh. Massachusetts’s average residential price was 30.5¢/kWh in August 2026, against 18.2¢ nationally, so that is about $64 a year; the most efficient certified model (16 CEER) cuts it to about $57.
Bedroom settings at night
A bedroom unit mostly runs at night. In EIA’s housing survey of air-conditioned homes under 1,000 sq ft, 34% keep the indoor temperature at 69°F or lower at night, 18% at 74–76°F, and 11% at 77°F or warmer. Each degree warmer at night lowers the hours the unit runs at full output.
In the same survey, window or wall units are the main cooling equipment in 37% of these homes, and portable units in 4%.
100, 150 and 180 sq ft
Smaller rooms are sized here too.
| Area | ENERGY STAR chart | Model load, moderate climate (BTU/h) |
|---|---|---|
| 100 sq ft | 5,000 BTU | 2,200 |
| 150 sq ft | 5,000 BTU | 3,300 |
| 180 sq ft | 6,000 BTU | 4,000 |
| 200 sq ft | 6,000 BTU | 4,400 |
Loads from this site’s sizing model (how it works): planning estimates, not a room-by-room load calculation.
Bigger room: 300 sq ft (7,000 BTU on the chart).
FAQ
Is 5,000 BTU enough for 200 sq ft?
Only if the room is heavily shaded. The chart gives 5,000 BTU up to 150 sq ft and 6,000 BTU for 150–250 sq ft; a 10% shade reduction brings 6,000 down to 5,400, and 5,000 BTU is 93% of that, inside the 90–115% range this site sizes to.
What size AC for a 10x10 room?
100 sq ft is the bottom of ENERGY STAR’s chart: 5,000 BTU.
What size AC for 150 sq ft?
5,000 BTU on ENERGY STAR’s chart. A 12 × 12 room (144 sq ft) also gets 5,000 BTU.
Is 8,000 BTU too much for 200 sq ft?
Yes. It is a third above the chart’s 6,000 BTU. An oversized room unit cools quickly and stops, so it removes less moisture.
Do small window AC units need a special outlet?
No. All certified 5,000 and 6,000–7,000 BTU window units in ENERGY STAR’s list run on 115 V.
Can a 1-ton AC cool 200 sq ft?
It can, but it is the wrong size. One ton is 12,000 BTU, twice the chart’s 6,000 for this room. A unit that large cools the air in a few minutes and shuts off, so the bedroom feels clammy.
Will a portable AC cool a 200 sq ft bedroom?
Yes, if you compare the right number. Portables are rated by SACC, a DOE figure that deducts the heat given off by the hose and the warm outside air the unit draws into the room; look for an SACC of about 6,000 BTU, not the larger number older boxes print. Check it with the portable AC calculator.
My bedroom has a 9 ft ceiling. Does that change the size?
Not usually. ENERGY STAR calculates its chart for an 8-foot ceiling. Our tools add about 10% per extra foot (this site’s planning estimate), so 6,000 becomes 6,600 BTU, and a 6,000 BTU unit is still 91% of that, inside the 90–115% range. Our tonnage calculator gives about 5,800 BTU/h for this room at 9 ft in a moderate US climate. See the ceiling height guide.
Sources used on this page
- ENERGY STAR: room air conditioners sizing chart — the chart size and its sun, people and kitchen adjustments
- ENERGY STAR Certified Room Air Conditioners dataset (data.energystar.gov) — certified window units by size: voltage, CEER, weight, mounting
- 10 CFR 430.32(b) and (cc): room and portable air conditioner standards (eCFR) — minimum CEER for units made from May 26, 2026
- EIA, 2020 Residential Energy Consumption Survey, Table HC7.9: air conditioning by home size — how homes under 1,000 sq ft are cooled
- EIA, Electric Power Monthly, Table 5.6.A: average price of electricity by state — Massachusetts residential electricity price
- NOAA NCEI: U.S. Climate Normals 1991–2020 — cooling degree days
actonnagecalc.com is not affiliated with, or endorsed by, the U.S. EPA, ENERGY STAR®, DOE or the ICC. Their publications are cited as sources.
Updated 6 November 2026