What Size AC for 800 Sq Ft?
ENERGY STAR’s room AC chart and its adjustments: −10% for heavy shade, +10% for a very sunny room, +600 BTU for each person beyond two, +4,000 BTU for a kitchen. The chart assumes 8 ft ceilings. Size to look for: the smallest chart size within 90–115% of the need (ENERGY STAR’s recommended range for single-speed central systems, which this site also uses for room units).
| Size to look for | — |
| Chart band | — |
| Your unit | — |
18,000 BTU for 800 sq ft
ENERGY STAR’s room AC chart gives 18,000 BTU for 700–1,000 sq ft. For an 800 sq ft apartment or small house that is about 1.5 tons. Our climate model lands close to the chart in a moderate climate (17,600 BTU/h) and well above it in the hottest (22,400 BTU/h).
| Summer climate | Example cities (cooling degree days) | Model load (BTU/h) | ENERGY STAR chart | Suggested size (the smallest chart size within 90–115% of the need: chart or model load, whichever is larger) |
|---|---|---|---|---|
| Hot | Houston, TX (3,288) | 22,400 | 18,000 BTU | 21,000 BTU (94%) |
| Warm | Dallas-Fort Worth, TX (2,824) | 20,000 | 18,000 BTU | 18,000 BTU (90%) |
| Moderate | Charlotte, NC (1,769) | 17,600 | 18,000 BTU | 18,000 BTU (100%) |
| Mild | Chicago, IL (1,003) | 16,000 | 18,000 BTU | 18,000 BTU (100%) |
| Cool | Minneapolis, MN (830) | 14,400 | 18,000 BTU | 18,000 BTU (100%) |
Model load for 800 sq ft from the site’s whole-home model; ENERGY STAR’s chart does not vary by climate. Cooling degree days: NOAA 1991–2020.
One unit or several?
An 800 sq ft home almost always has walls and doors, and one window unit cools the room it sits in. The capacity has to be split between rooms:
| Size (BTU/h) | Certified window models | On 115 V | CEER | At May 2026 minimum | Weight (lb) | Saddle-mount | Listed kWh/yr (avg) |
|---|---|---|---|---|---|---|---|
| 8,000 (7,500–8,999) | 125 | 125 of 125 | 13.2–17 | 61 | 33–100 | 53 | 398 |
| 12,000 (12,000–13,999) | 123 | 119 of 123 | 13.3–16.8 | 40 | 50–120 | 60 | 595 |
| 18,000 (16,000–19,999) | 30 | 0 of 30 | 14.4–16 | 11 | 85–130 | 9 | 890 |
ENERGY STAR certified window units, retrieved 2026-11-05. Minimum CEER for units made from May 26, 2026 from 10 CFR 430.32(b)(2), checked per product class.
- One 18,000 BTU unit: all 30 certified models need a 230 V circuit and weigh 85–130 lb. It suits a mostly open plan.
- Two units: a 12,000 BTU unit for a living area of about 350 sq ft with the kitchen open to it (8,000 on the chart plus ENERGY STAR’s 4,000 BTU kitchen allowance) and an 8,000 BTU unit for the bedroom total 20,000 BTU, and both usually run on 115 V (119 of 123 and 125 of 125 certified models).
- Multi-zone mini-split: one outdoor unit around 1.5–2 tons with a head in each main room.
Small homes already work this way: in EIA’s survey of air-conditioned homes under 1,000 sq ft, 46% of those using window or wall units run two or more.
Mini-split sizes for 800 sq ft
ENERGY STAR lists 3,754 certified ductless combinations around 1.5 tons and 2,410 around 2 tons; all are variable-speed.
| Size (rated BTU/h) | Certified combinations | Cold-climate | SEER2 |
|---|---|---|---|
| 1.5 ton (16,000–19,999) | 3,754 | 82% | 15.2–27.5 (avg 20.9) |
| 2 ton (22,000–25,999) | 2,410 | 90% | 15.6–27 (avg 20.8) |
ENERGY STAR certified ductless mini- and multi-split heat pumps, retrieved 2026-11-05.
Worked example: a shaded 800 sq ft apartment in Chicago
An 800 sq ft apartment on a tree-lined street, mostly shaded, two occupants. Chart: 18,000 BTU; heavy shade −10%: 16,200 BTU, still an 18,000 BTU purchase if it is one unit and the kitchen is closed off. If that one unit also cools an open kitchen, ENERGY STAR adds 4,000 BTU, which takes the need past what an 18,000 BTU unit delivers; that is the point where two units or a multi-zone mini-split make more sense. Chicago’s 1,003 cooling degree days a year are about a third of Houston’s 3,288.
At 500 full-output hours a year (labelled assumption) and the 15.2 CEER certified average, one 18,000 BTU unit uses about 593 kWh: about $115 a year at Illinois’s 19.3¢/kWh (August 2026).
Around 800 sq ft
| Area | ENERGY STAR chart | Model load, moderate climate (BTU/h) |
|---|---|---|
| 800 sq ft | 18,000 BTU | 17,600 |
Loads from this site’s sizing model (how it works): planning estimates, not a room-by-room load calculation.
600 sq ft is 14,000 BTU on the chart. At 1,000 sq ft the page compares window units with central air.
FAQ
Is 12,000 BTU enough for 800 sq ft?
For the whole space, no: the chart gives 18,000 BTU. One 12,000 BTU unit can cool the main room of an 800 sq ft home, with a second unit for the bedroom.
How many tons for 800 sq ft?
About 1.5 tons (18,000 BTU) on ENERGY STAR’s chart. Our model load ranges from 14,400 BTU/h in the cool North to 22,400 BTU/h in the hottest climates.
Does an 18,000 BTU AC need 230 V?
Yes: all 30 certified 18,000 BTU window models in ENERGY STAR’s list need a 230 V circuit.
What size mini-split for 800 sq ft?
About 1.5 tons in total, more in hot climates. With separate rooms, use a multi-zone system with a head per room.
Can one window AC cool an 800 sq ft apartment?
Only an open-plan one. Doors and hallways block the airflow, so rooms away from the unit stay warmer.
Can a portable AC cool 800 sq ft?
Only if its SACC rating reaches the chart’s 18,000 BTU. SACC is the DOE rating after deducting heat from the hose and from the outside air the unit draws into the room; check that number, not a bigger figure on an older box. With separate rooms, one unit per room or a multi-zone mini-split cools more evenly.
What about an 800 sq ft loft with high ceilings?
Size it by volume. ENERGY STAR’s 18,000 assumes 8 ft; at 10 ft, adding about 10% per foot (this site’s planning estimate) gives 21,600 BTU, which means a 21,000 BTU window unit on 230 V (97%), the smallest chart size within 90–115%, or a 2-ton mini-split (111%). See the ceiling height guide.
Sources used on this page
- ENERGY STAR: room air conditioners sizing chart — the chart size and its sun, people and kitchen adjustments
- ENERGY STAR Certified Room Air Conditioners dataset (data.energystar.gov) — certified window units by size: voltage, CEER, weight, mounting
- 10 CFR 430.32(b) and (cc): room and portable air conditioner standards (eCFR) — minimum CEER for units made from May 26, 2026
- EIA, 2020 Residential Energy Consumption Survey, Table HC7.9: air conditioning by home size — how homes under 1,000 sq ft are cooled
- EIA, Electric Power Monthly, Table 5.6.A: average price of electricity by state — Illinois residential electricity price
- NOAA NCEI: U.S. Climate Normals 1991–2020 — cooling degree days
- ENERGY STAR Certified Heat Pumps dataset (data.energystar.gov) — certified ductless mini-split combinations
actonnagecalc.com is not affiliated with, or endorsed by, the U.S. EPA, ENERGY STAR®, DOE or the ICC. Their publications are cited as sources.
Updated 6 November 2026