American Standard uses the same key as its sister brand Trane: characters 6–8 are the capacity in thousands of BTU/hr, so 4A7A6036J1000A = 3 tons. Paste your model number below.

American Standard air conditioner model number 4A7A6036J1000A with the capacity code 036 highlighted
Which characters in an American Standard model number carry the capacity code.
American Standard 4A7A6036J1000A: 3 tons. Characters 6–8 are thousands of BTU/h (036). On serials from 2010 on, the first two digits are the year and the next two the week, so 24061381FA was built in week 6 of 2024.
Enter a model number…

Examples from American Standard’s own documents

Each model below is printed in the American Standard document linked beside it, with the capacity that document gives. Type any of them into the decoder to see how it is read.

Model (as printed)CodeCapacity in the documentDocument
A5AC4036B1000A03636,000 BTU/hr (Ameristar)Trane / American Standard Product & Submittal Data ODR-PSD031C-EN
A5AC4048B1000A04848,000 BTU/hr (Ameristar)Trane / American Standard Product & Submittal Data ODR-PSD031C-EN
4A7A6036J1000A0363 tonsAmerican Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6
4A7A6049J1000A049Listed; capacity not stated (same compressor as 048)American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6
4A7A7048B1000A0484 tonsAmerican Standard 4A7A7048B product specifications

Always confirm against the rated-capacity line on your own unit’s data plate.

American Standard capacity codes

American Standard models use Trane’s three-digit size field. The codes listed are those printed in the American Standard and Trane documents cited beside them.

CodeNominal BTU/hrTonsDefined in
01818,0001.5American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6
02424,0002American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6
03030,0002.5American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6
03636,0003American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6
04242,0003.5American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6
04848,0004American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6
049not stated4American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6 (model listed, capacity not stated; same compressor as 048)
06060,0005American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6
061not stated5American Standard Product Data 12-1376-1A-EN, Split System Cooling 4A7A6 (model listed, capacity not stated; same compressor as 060)

The size field is nominal. AHRI-certified capacity, which depends on the indoor coil it is paired with, is in the AHRI Directory.

How to read a American Standard model number

American Standard is part of Trane Technologies, and its product data uses the same table layout as Trane's. Reading 4A7A6036J1000A:

CharactersIn 4A7A6036J1000AMeaning (American Standard key)
14Refrigerant: 4 = R-410A
2AAmerican Standard
377 = split cooling, 6 = split heat pump
4AProduct family
56Family SEER (6 = 16)
6–8036Nominal capacity in thousands of BTU/hr
9–14J1000ADesign series, voltage and revisions

The 4A7A6 model list also includes 4A7A6049 and 4A7A6061. The sheet gives no capacity for them, but they use the same compressor as the 048 and 060 units, so the decoder reads 049 as 4 tons and 061 as 5 tons. Check the data plate to confirm.

Ameristar by American Standard

Ameristar models start with A and follow the same layout: A5AC4036B1000A = R-454B (5), air conditioner (AC), 14.3 SEER2 (4), 36,000 BTU/hr at characters 6–8.

How old is my American Standard? Serial number decoder

American Standard is a sister brand of Trane, and the same CPSC recall notice covers both: their serials begin with the year and fiscal week of manufacture. We found no American Standard document that gives the layout.

Enter a serial number…

American Standard serial date code

  • First two characters: year
  • Next two: week

A serial such as 2406… means week 6 of 2024.

Covers: newer serials that start with a two-digit year. Two-digit years are read as the most recent matching year.

Where to find the serial: AC and heat pumps: top right rear of the outdoor unit; furnaces: a side panel; air handlers and coils: the front panel.

Sources

What American Standard has certified with ENERGY STAR

American Standard has 6,017 heat pump combinations on ENERGY STAR’s list (retrieved 2026-11-05): 5,993 ducted split, 12 ductless and 12 packaged, from 88 outdoor models.

Most outdoor models start 5A (4,222 combinations, 30 outdoor units, up to 22.4 SEER2) or 4A (1,384). Two smaller groups, N (314) and 5HPL (59), appear with exactly the same counts under Trane, so those outdoor units are listed under both names.

Outdoor model number starts withCombinationsOutdoor modelsSizes (tons)SEER2
5A4,222301.5–515.2–22.4
4A1,384162–517–20.5
N31471.5–515.2–16
5HPL5962–415.2–16
5HCL923–516–19
4TXD423–516–17

Grouped by the leading characters of the outdoor model number as listed by ENERGY STAR. Sizes are nominal: read from each model’s capacity code and checked against its rated capacity.

Compared with Trane (25% variable-speed), American Standard’s list has more variable-speed combinations (39%) and fewer two-stage (20%). The size mix centres on 3 tons (2,178).

Decoders for other brands

Amana Blue Star Bryant Carrier Daikin Goodman Heil Hitachi Lennox LG Lloyd O General Panasonic Payne Rheem Ruud Samsung Trane Voltas Whirlpool York

FAQ

Where do I find the model number on an American Standard AC?

On the rating plate at the top right of the outdoor unit’s back panel.

How do I read an American Standard model number?

It follows Trane’s layout: character 1 = refrigerant (4 = R-410A, 5 = R-454B), 4A7 = air conditioner, 4A6 = heat pump, characters 6–8 = capacity. 4A7A6036J1000A: 036 = 3 tons.

What tonnage is an American Standard A5AC4036B1000A?

36,000 BTU/hr (3 tons), per Trane/American Standard submittal data ODR-PSD031C-EN.

How old is my American Standard unit?

Year, then week, in the first four characters of newer serials.

Is American Standard the same as Trane?

They share a serial format and some certified outdoor units: the N (314 combinations) and 5HPL (59) groups appear with identical counts under both names in ENERGY STAR’s list. Most American Standard models (5A, 4A) carry their own numbers.

How many American Standard heat pumps are ENERGY STAR certified?

6,017 combinations from 88 outdoor models; 39% are variable-speed.

What does a 5A model number mean on American Standard?

In ENERGY STAR’s list, outdoor models starting 5A are American Standard’s largest group: 4,222 combinations from 30 outdoor units, 1.5–5 tons. The leading 5 is the R-454B refrigerant digit in Trane’s key.

Does American Standard make 5-ton heat pumps?

Few are certified: 7 ENERGY STAR combinations at 5 tons, against 2,178 at 3 tons.

Sources & standards

American Standard shares Trane’s documentation, so several sources below are Trane product data that cover both names.

Ameristar and RunTru units built by the same company use their own model prefixes.

Different brand? Back to the model number lookup. Sizing a replacement? Check what your space really needs with the AC tonnage calculator first — the old unit may have been mis-sized.