Amana uses the same key as Goodman with A as the brand letter. In ALXS4BA3610AA, characters 8–9 are the capacity: 36 = 3 tons. Paste your model number below.
Each model below is printed in the Amana document linked beside it, with the capacity that document gives. Type any of them into the decoder to see how it is read.
| Model (as printed) | Code | Capacity in the document | Document |
|---|---|---|---|
| ALXS4BA3610AA | 36 | 3 tons | Amana SS-ALXS4B-R32 Technical Specifications |
| ASX160241F* | 24 | 23,600 BTU/hr rated (2-ton size) | Amana SS-ASX16 Product Specifications |
| ANX140241B* | 24 | 24,000 BTU/hr | Amana SS-ANX14 Product Specifications |
| ANX140191A* | 19 | 18,000 BTU/hr | Amana SS-ANX14 Product Specifications |
An asterisk (*) is part of how the document lists the model; it stands for trailing characters that vary. Always confirm against the rated-capacity line on your own unit’s data plate.
Only codes that appear in the Amana documents we checked are listed, and the decoder uses exactly this table.
| Code | Nominal BTU/hr | Tons | Defined in |
|---|---|---|---|
| 18 | 18,000 | 1.5 | Amana SS-ASX16 Product Specifications |
| 19 | 18,000 | 1.5 | Amana SS-ANX14 Product Specifications |
| 24 | 24,000 | 2 | Amana SS-ASX16 Product Specifications |
| 25 | 24,000 | 2 | Amana SS-ANX14 Product Specifications |
| 30 | 30,000 | 2.5 | Amana SS-ASX16 Product Specifications |
| 31 | 30,000 | 2.5 | Amana SS-ANX14 Product Specifications |
| 36 | 36,000 | 3 | Amana SS-ASX16 Product Specifications |
| 37 | 36,000 | 3 | Amana SS-ANX14 Product Specifications |
| 42 | 42,000 | 3.5 | Amana SS-ASX16 Product Specifications |
| 43 | 42,000 | 3.5 | Amana SS-ANX14 Product Specifications |
| 48 | 48,000 | 4 | Amana SS-ASX16 Product Specifications |
| 60 | 60,000 | 5 | Amana SS-ASX16 Product Specifications |
Nominal size is not the same as rated capacity: a unit sold as 4 tons may be rated a little below 48,000 BTU/hr. The rated figure is on the data plate and in the AHRI Directory.
Amana's specification sheets use the same layout as Goodman's, with A as the brand letter.
ALXS4BA3610AA: A = Amana, L = R-32 split system, X = condenser (Z = heat pump), S = single-stage, 4 = SEER2 band, B = standard, A = all regions, 36 = 3 tons at characters 8–9. amana-hac.com lists ALXS3B, ALXS4B, ALXS5B, ALXT7C and the variable-speed AXV6S and AXV9S in its current range.
ASX160361: S = split system, X = condenser, 16 = SEER, 0, then 36. The ANX14 sheet also uses alternate codes for the same sizes: ANX140191 is an 18,000 BTU/hr (1½-ton) unit.
We have not found an Amana sheet for the AXV variable-speed models, so the decoder does not read them yet; Amana's split-system sheets list 18 to 60 only (no 09 or 12).
Amana serial numbers carry the date the unit was built. Type the serial from the rating plate. Amana residential equipment is built by Goodman (now Daikin Comfort) and official recall notices list Amana units under the same serial prefixes as Goodman. The year-then-month layout is confirmed by Goodman's own bulletin and those notices.
Example: 1804165082 = April 2018 (Goodman bulletin SP-039 lists this unit as built 4/11/2018).
Covers: Amana-branded US equipment built by Goodman (10-digit serials, 2003 on). Two-digit years are read as the most recent matching year.
Caveat: CPSC recorded that some evaporator coils built January 2019 to early 2020 were wrongly stamped with 2018 serials (prefixes 1811-1812), so a coil reading Nov or Dec 2018 may be newer.
Where to find the serial: on outdoor units the nameplate is on the panel next to or above the refrigerant line connections; on furnaces it is on a side panel behind the front panel.
American Standard Blue Star Bryant Carrier Daikin Goodman Heil Hitachi Lennox LG Lloyd O General Panasonic Payne Rheem Ruud Samsung Trane Voltas Whirlpool York
On the rating plate (data plate) of the outdoor unit — a metal or foil label on a side or back panel. Use the model number for tonnage; the serial number carries the build date (see how old is my unit).
Amana uses Goodman’s layout with A as the brand letter. On current R-32 models the capacity is at characters 8–9 (ALXS4BA3610AA = 36 = 3 tons); on ASX and ANX models it is characters 7–8 (ASX160241 = 24 = 2 tons). Codes 19, 25, 31, 37 and 43 are alternates for the same sizes.
Type the outdoor unit’s model number into the decoder above; it applies the layout from Amana’s own documents. For example, ALXS4BA3610AA is listed in Amana SS-ALXS4B-R32 Technical Specifications at 3 tons. If the decoder only gives a generic match, read the rated capacity on the data plate.
Read the serial number on the rating plate. The first two digits are the year and the next two the month it was built. For example, 1804165082 = April 2018 (Goodman bulletin SP-039 lists this unit as built 4/11/2018).
Everything on this page about Amana model numbers comes from the Amana documents below. Where a manufacturer’s own file is only available from a distributor’s server, the note says so.
Tonnage is nominal cooling capacity divided by 12,000 BTU/hr per ton.
Manufacturers change model formats over time. The rated-capacity line on the unit’s data plate is always authoritative; figures here are for identification, not a substitute for a load calculation.
Different brand? Back to the model number lookup. Sizing a replacement? Check what your space really needs with the AC tonnage calculator first — the old unit may have been mis-sized.