From Ruud’s own documents

Ruud Model & Serial Number Lookup

Built by Murugan Vellaichamy, Sri Murugan Systems · sources checked November 2026 · how the numbers work

Ruud uses Rheem’s key, and most Ruud air conditioners start with RA, not UA. In RA14AY36AJ1NA, characters 7–8 = 36,000 BTU/hr = 3 tons. Paste your model number below.

Ruud air conditioner model number RA14AY36AJ1NA with the capacity code 36 highlighted
Which characters in a Ruud model number carry the capacity code.
Ruud RA14AY36AJ1NA: 3 tons. Ruud uses Rheem’s key, so characters 7–8 are thousands of BTU/h. Serials with an M date code give the week, then the year (M3595 = week 35 of 1995); for newer serials, check the plate for a date or ask a Ruud dealer.
Enter a model number…

Examples from Ruud’s own documents

Each model below is printed in the Ruud document linked beside it, with the capacity that document gives. Type any of them into the decoder to see how it is read.

Model (as printed)CodeCapacity in the documentDocument
RA14AY36AJ1NA3636,000 BTU/hr (3 tons)Ruud RA14AY Endeavor Line Achiever Series — model list
RA14AY60AJ1NA6060,000 BTU/hr (5 tons)Ruud RA14AY Endeavor Line Achiever Series — model list
RA1648AJ1NA4848,000 BTU/hr (4 tons)Ruud RA16 specification sheet, Form A22-222

Always confirm against the rated-capacity line on your own unit’s data plate.

Ruud capacity codes

Each code below appears in a Ruud model list or specification sheet linked in its row. Anything outside this table is reported as unrecognised rather than guessed.

CodeNominal BTU/hrTonsDefined in
1818,0001.5Ruud RA14AY Endeavor Line Achiever Series — model list
2424,0002Ruud RA14AY Endeavor Line Achiever Series — model list
3030,0002.5Ruud RA14AY Endeavor Line Achiever Series — model list
3636,0003Ruud RA14AY Endeavor Line Achiever Series — model list
4242,0003.5Ruud RA14AY Endeavor Line Achiever Series — model list
4848,0004Ruud RA14AY Endeavor Line Achiever Series — model list
6060,0005Ruud RA14AY Endeavor Line Achiever Series — model list

A code gives the size class only; Ruud’s certified capacity for a given outdoor and indoor pairing is in the AHRI Directory and on the plate.

How to read a Ruud model number

Ruud and Rheem are sister brands and share one key. On Ruud's own RA16 sheet the first letter R stands for Ruud, and Ruud's catalog lists its split air conditioners as RA13NY, RA14AY, RA15AY, WA13NY, WA14AY, WA15AY, WSA14AY, UA16AY and UA19AY. Only the Achiever Plus (UA16AY) and Ultra (UA19AY) lines use a UA prefix.

Current Endeavor models

RA14AY36AJ1NA: R, A = air conditioner, 14 = efficiency series, A = region, Y = R-454B (Z = R-410A), then 36 = 36,000 BTU/hr at characters 7–8. Ruud's catalog lists RA14AY18 through RA14AY60, from 1.5 to 5 tons.

Older RA16 models

RA1648AJ1NA: R, A, 16 SEER, then 48 = 4 tons at characters 5–6.

Ruud’s catalog lists UA16AY24/36/48/60AJ2N and UA19AY24/36/48/60AJVCA (24,000–60,000 BTU/hr) with the size at characters 7–8. The decoder reads these lines with the same size position.

Heat pumps (RP, RD, UP)

Rheem’s RP14AY sheet uses the same key with P = heat pump, and Ruud’s RD17AZ flyer lists RD17AZ24, 36, 48 and 60AJ3NA as 2, 3, 4 and 5 tons, so the decoder reads RP, RD and UP models from characters 7–8 too.

How old is my Ruud? Serial number decoder

Ruud serials are dated the same way as Rheem’s: a 2009 CPSC recall notice covering both brands gives the four digits after the letter M as the date code, and a 1999 Rheem notice reads them as the week and year of manufacture. We found no Ruud document that gives the layout.

Enter a serial number…

Ruud M-code example

  • Serial contains M3595
  • 35 = week 35
  • 95 = 1995

Covers: serials with an M date code (about 1992-2008). Two-digit years are read as the most recent matching year.

Sources

What Ruud has certified with ENERGY STAR

Ruud has 1,610 heat pump combinations in ENERGY STAR’s list (retrieved 2026-11-05), 1,555 of them ducted split, from 89 outdoor models. Most outdoor model numbers are shared with one other name: Rheem (85).

Ruud’s list has one group Rheem’s does not: UP (100 combinations, 18–21 SEER2). Its RP group tops out at 17 SEER2 against 21 for Rheem’s.

Outdoor model number starts withCombinationsOutdoor modelsSizes (tons)SEER2
RP614221.5–515.2–17
RD575122–515.2–20
WP266181.5–515.2–16
UP10042–418–21

Grouped by the leading characters of the outdoor model number as listed by ENERGY STAR. Sizes are nominal: read from each model’s capacity code and checked against its rated capacity.

Staging matches Rheem’s closely: 65% variable-speed and 35% two-stage, with 72% cold-climate. By size, 497 combinations at 3 tons and 110 at 5 tons.

Decoders for other brands

Amana American Standard Blue Star Bryant Carrier Daikin Goodman Heil Hitachi Lennox LG Lloyd O General Panasonic Payne Rheem Samsung Trane Voltas Whirlpool York

FAQ

Where do I find the Ruud model number?

Check the rating plate on the outdoor unit.

How do I read a Ruud model number?

Ruud uses Rheem’s key. RA14AY36AJ1NA has the size at characters 7–8 (36 = 3 tons); older RA16 models at 5–6 (RA1648AJ1NA = 4 tons). Only the UA16AY and UA19AY lines start with UA.

What tonnage is a Ruud RA14AY36AJ1NA?

36,000 BTU/hr, 3 tons, per Ruud’s RA14AY Endeavor Line model list.

How old is my Ruud unit?

Look for M plus four digits in the serial: week, then year.

What does Ruud certify that Rheem doesn’t?

The UP outdoor group: 100 ENERGY STAR combinations at 18–21 SEER2.

How many Ruud heat pumps are ENERGY STAR certified?

1,610 combinations, from 89 outdoor models; 72% are cold-climate.

What sizes are certified Ruud heat pumps?

Mostly mid-size: 497 ENERGY STAR combinations at 3 tons and 288 at 3.5, against 44 at 1.5 tons and 167 at 2.

What are Ruud RD outdoor units?

In ENERGY STAR’s list, Ruud outdoor models starting RD account for 575 combinations across 2–5 tons, rated 15.2–20 SEER2.

Sources & standards

Ruud model lists and spec sheets supply the model rules; the M-code serial dating comes from Rheem/Ruud recall notices.

Ruud’s UA16AY and UA19AY lines, and its WA13NY, WA14AY, WA15AY and WSA14AY models, do not use the RA prefix.

Different brand? Back to the model number lookup. Sizing a replacement? Check what your space really needs with the AC tonnage calculator first — the old unit may have been mis-sized.

Updated 6 November 2026