What Size AC for 400 Sq Ft?
ENERGY STAR’s room AC chart and its adjustments: −10% for heavy shade, +10% for a very sunny room, +600 BTU for each person beyond two, +4,000 BTU for a kitchen. The chart assumes 8 ft ceilings. Size to look for: the smallest chart size within 90–115% of the need (ENERGY STAR’s recommended range for single-speed central systems, which this site also uses for room units).
| Size to look for | — |
| Chart band | — |
| Your unit | — |
9,000 or 10,000 BTU for 400 sq ft?
A 400 sq ft room (20 × 20 ft, or 16 × 25 ft) is the top of the 350–400 sq ft band in ENERGY STAR’s room AC chart, which gives 9,000 BTU. The next band, 400–450 sq ft, gives 10,000. A living room this size often has three people in it in the evening; the chart adds 600 BTU for each regular occupant beyond two, which takes 9,000 to 9,600. A 9,000 BTU unit is 94% of that, inside the 90–115% range this site sizes to, and a 10,000 BTU unit (104%) also fits.
Our climate model gives a similar picture: 8,800 BTU/h for 400 sq ft in a moderate climate, 10,000 in the warm South and 11,200 in the hottest areas, where a 12,000 BTU unit fits better.
Certified 8,000–10,000 BTU window units
This is the most crowded part of the market: 125 certified models from 7,500 to 8,999 BTU and 114 from 9,000 to 11,999.
| Size (BTU/h) | Certified window models | On 115 V | CEER | At May 2026 minimum | Weight (lb) | Saddle-mount | Listed kWh/yr (avg) |
|---|---|---|---|---|---|---|---|
| 8,000 (7,500–8,999) | 125 | 125 of 125 | 13.2–17 | 61 | 33–100 | 53 | 398 |
| 10,000 (9,000–11,999) | 114 | 111 of 114 | 13.2–17.6 | 51 | 43–140 | 59 | 487 |
ENERGY STAR certified window units, retrieved 2026-11-05. Minimum CEER for units made from May 26, 2026 from 10 CFR 430.32(b)(2), checked per product class.
- Saddle-mount units: 52% of the certified 9,000–11,999 BTU models straddle the window or sill rather than sitting fully in the opening.
- Heat and cool: 15 certified models at 9,000–11,999 BTU are reverse-cycle units that also heat. Their federal minimum from May 26, 2026 is CEER 14.4 instead of 16.0.
- The 2026 rule: units without heat made from May 26, 2026 need CEER 16.0 at 8,000–13,900 BTU. 51 of 114 certified 9,000–11,999 BTU models meet their class minimum today; units made before that date can still be sold, so check the CEER on the box.
Worked example: a Texas living room
A 400 sq ft living room with average sun, three regular occupants. Chart: 9,000 BTU, plus 600 for the third person: 9,600 BTU. The smallest chart size within 90–115% of that is 9,000 BTU (94%), the size the tool above suggests.
Texas summers are long, so we assume 1,400 full-output hours a year (labelled). At the 15.5 CEER average for certified units this size that is about 814 kWh, about $129 at the Texas average of 15.9¢/kWh (August 2026). The best certified model, 17.6 CEER, would cost about $114.
Who controls the AC
Many small homes are rentals or apartments. In EIA’s survey of air-conditioned homes under 1,000 sq ft, 6% of households have no control over their AC. Where they do, 7% keep it at 80°F or warmer when someone is home. Window or wall units are the main cooling in 37% of these homes.
Neighbouring sizes
| Area | ENERGY STAR chart | Model load, moderate climate (BTU/h) |
|---|---|---|
| 400 sq ft | 9,000 BTU | 8,800 |
Loads from this site’s sizing model (how it works): planning estimates, not a room-by-room load calculation.
FAQ
Is 8,000 BTU enough for 400 sq ft?
Only for a shaded room used by one or two people. The chart gives 9,000 BTU; with heavy shade that drops to 8,100, and an 8,000 BTU unit is 99% of that.
Is 10,000 BTU good for 400 sq ft?
Yes, if the room is sunny or has three or more regular occupants. Otherwise it is one size above the chart’s 9,000 BTU, which is still acceptable.
Is 12,000 BTU too much for 400 sq ft?
For most rooms, yes: a third above the chart. It makes sense in the hottest climates, where our model load is 11,200 BTU/h.
What size AC for a 20x20 room?
20 × 20 ft is 400 sq ft: 9,000 BTU on ENERGY STAR’s chart.
Can a window AC also heat?
Yes. 15 certified models at 9,000–11,999 BTU are heat-and-cool (reverse-cycle) units.
Is a 1-ton AC enough for 400 sq ft?
More than enough: a ton is 12,000 BTU, a third above the chart’s 9,000 BTU (0.75 ton). Search results that suggest 1.5–2 tons for 400 sq ft are two to three times the ENERGY STAR size.
Is 2 ton AC enough for 400 sq ft?
More than enough, and too much for one room. Two tons is 24,000 BTU, over two and a half times the chart’s 9,000 BTU for 400 sq ft. ENERGY STAR warns that an oversized unit cools the room quickly and shuts off before it has removed the humidity, so the room feels cold and damp.
Can a portable AC cool a 400 sq ft living room?
Only a large one. Look for about 9,000–10,000 BTU SACC, the DOE rating that counts heat lost through the hose. Size one with the portable AC calculator.
Does a vaulted ceiling need a bigger unit?
Usually one size up. ENERGY STAR’s chart assumes 8 ft; use the average ceiling height and add about 10% per foot above 8. At an 11 ft average, 9,000 becomes 11,700 BTU (this site’s planning estimate), so a 12,000 BTU unit (103%). See the ceiling height guide.
Sources used on this page
- ENERGY STAR: room air conditioners sizing chart — the chart size and its sun, people and kitchen adjustments
- ENERGY STAR Certified Room Air Conditioners dataset (data.energystar.gov) — certified window units by size: voltage, CEER, weight, mounting
- 10 CFR 430.32(b) and (cc): room and portable air conditioner standards (eCFR) — minimum CEER for units made from May 26, 2026
- EIA, 2020 Residential Energy Consumption Survey, Table HC7.9: air conditioning by home size — how homes under 1,000 sq ft are cooled
- EIA, Electric Power Monthly, Table 5.6.A: average price of electricity by state — Texas residential electricity price
- NOAA NCEI: U.S. Climate Normals 1991–2020 — cooling degree days