HVAC load estimate · No signup · Free

AC Tonnage Calculator: what size air conditioner do you actually need?

Built by Murugan Vellaichamy, Sri Murugan Systems · sources checked November 2026 · how the numbers work

A 1,500 sq ft home in a moderate US climate needs about a 2.5-ton (30,000 BTU) air conditioner on this site’s planning estimate — but climate, sun exposure, ceilings and insulation can shift that by a full ton. Enter your real room data below to get the exact tonnage, BTU and running cost.

01 · Room & Building
02 · Climate & Exposure
Sets the climate band for you.
03 · Heat Load Details

Estimate only — confirm equipment sizing with a Manual J load calculation by a licensed contractor.

Result
—TONS
Buy a — unit
Cooling load—
Thermal power—
Floor area—
Duct airflow needed—
Load breakdown
Base (area × climate)Ceiling · sun · roof · insulationPeople · kitchen · equipmentWindows
Running cost estimate
— / month
Your utility’s own rate: utilityratecalc.com uses the official tariffs of 112 US utilities.
Whole House →

All Calculators

Every tool runs entirely in your browser. No accounts, no uploads, no tracking of your inputs.

TOOL · 02

Model Number → Tonnage Decoder

Paste your AC's model number (Goodman, Carrier, Trane, Voltas, LG…) and we'll decode its tonnage from the capacity code; Indian brands are checked against the BEE star label.

→
TOOL · 03

Whole-House Calculator

Add every room, sum the loads, and get a central-system size or per-room split AC plan — no signup required.

→
TOOL · 04

AC Electricity Bill Calculator

Monthly running cost from tonnage, star rating / SEER2, daily hours and your local tariff.

→
TOOL

Furnace Size Calculator

Heat loss at your county’s winter design temperature, and the furnace output range ENERGY STAR allows.

→
TOOL

Heat Pump Size Calculator

Cooling-anchored sizing with balance point and backup heat for your county.

→
TOOL

SEER2 Savings Calculator

Yearly savings and payback from a higher-efficiency AC or heat pump.

→
TOOL · 05

BTU ⇄ Tons ⇄ kW Converter

Instant conversions between BTU/hr, refrigeration tons, kilowatts, kcal/hr and horsepower.

→
TOOL · 06

Portable AC (SACC) Calculator

Portable units carry more than one capacity figure. Size by the DOE's derated SACC rating instead.

→
TOOL · 07

AC Ampere Calculator

Estimated running amps by tonnage, and how the nameplate MCA and MOCP set the wire and breaker.

→
TOOL · 08

Mini-Split Calculator

Per-zone ductless sizing with multi-zone totals, from 6,000 BTU bedrooms to 36,000 BTU open plans.

→
TOOL · 09

Window AC Calculator

Right-size a 5,000–34,000 BTU window unit for a single room without overshooting.

→
TOOL · 10

Commercial Tonnage Calculator

Offices, shops and server rooms — heavier occupant and equipment loads handled properly.

→
TOOL · 11

Duct Size & CFM Calculator

Airflow (CFM) and round or rectangular duct sizing by system tonnage and duct role.

→

Quick Sizing Chart

Typical size by home area — moderate US climate (Zone 3), average insulation, 8 ft ceilings. Sizes are the standard sizes within 90–115% of the load (ENERGY STAR’s recommended range); loads are this site’s planning estimate.

AreaCooling loadAC size
600 sq ft (one room)13,200 BTU/hr12,000–14,000 BTU room unit
1,000 sq ft21,000 BTU/hr2 ton
1,500 sq ft29,500 BTU/hr2.5 ton
2,000 sq ft37,800 BTU/hr3–3.5 ton
2,500 sq ft45,800 BTU/hr3.5–4 ton
3,000 sq ft53,800 BTU/hr5 ton

Detailed pages by size: 200 · 300 · 400 · 500 · 600 · 800 · 1,000 · 1,200 · 1,500 · 1,600 · 1,800 · 2,000 · 2,500 · 3,000 sq ft · full chart

Sizing by Space

Garages, sunrooms, server rooms and classrooms don't follow bedroom math — each page below explains that space's load physics with a calculator pre-tuned for it.

SPACE

Garage

A two-car garage carries loads a same-size bedroom never sees: the envelope is usu…

→
SPACE

Garage Gym

ENERGY STAR’s room AC chart allows 600 BTU/hr per extra person at rest; someone mid-workout puts out more, so a home gym needs far more cooling than its size suggests…

→
SPACE

Bedroom

Low internal gains (two sleeping people, no appliances), night-time operation when outdoor temp…

→
SPACE

Living Room

A living room's load swings more than any other room: two people watching TV on a Tuesday, ten …

→
SPACE

Kitchen

Cooking appliances dump roughly 4,000 BTU/hr of ambient heat into the room while in use — a gas…

→
SPACE

Sunroom

Standard sizing assumes walls that resist heat; a sunroom's envelope is designed to admit it. S…

→
SPACE

Attic Room / Loft Conversion

An attic room doesn't sit under a roof — it sits inside one. Heat soaks through the sl…

→
SPACE

Basement

Below-grade walls sit against cool earth — a basement's sensible cooling load is a fraction of…

→
SPACE

Home Office

A desktop workstation, two monitors and peripherals turn their power draw into heat — 3.412 BTU/hr per watt…

→
SPACE

Server Room / IT Closet

Electronics turn nearly all input power into heat, so server rooms are sized on equipment watts (BTU/hr = watts × 3.412), not floor area…

→
SPACE

Retail Shop

Retail loads stack three things homes don't: door-opening infiltration every few minutes (a gla…

→
SPACE

Restaurant Dining Area

A seated diner adds ~600 BTU/hr; a full 24-cover dining room carries roughly 13,000 BTU/hr of extra load from people, lighting and kitchen heat…

→
SPACE

Salon / Parlour

A hair dryer is a heat gun — every watt it draws adds 3.412 BTU/hr while running. With two or three…

→
SPACE

Gym / Fitness Studio

Fifteen people training add a heavy load of body heat and a torrent of…

→
SPACE

Classroom / Coaching Centre

A classroom is the purest occupancy-driven load: 30 students at 600 BTU each (ENERGY STAR’s per-person figure) is about 18,000 BTU/hr before sun and equipment…

→
SPACE

Mobile / Manufactured Home

Manufactured homes stack several load multipliers at once, starting with thin wall cavities…

→
SPACE

Conservatory

A conservatory is glazing on five of six surfaces — including the roof, the worst one. Summer s…

→
SPACE

Study / Small Room

A 90 sq ft study with one occupant and a laptop carries one of the lightest loads in the house …

→

Frequently Asked Questions

Straight answers, sized for both US central systems and Indian split ACs.

How many square feet does 1 ton of AC cool?

In a moderate US climate, 1 ton (12,000 BTU/hr) cools roughly 450-550 sq ft of average-insulated space. In India mode, this site’s planning estimate puts 1 ton at a room of about 115 sq ft in hot cities, about 125 sq ft in composite ones and about 155 sq ft in Bengaluru (9.5 ft ceiling, 3 people).

What happens if my AC is oversized?

An oversized unit cools the air quickly but shuts off before removing humidity — a behavior called short-cycling. You get a cold, clammy room, more compressor wear, and a higher bill.

How do I find the tonnage of my existing AC?

It's coded in the outdoor unit's model number, not the serial number. Look for a two-digit group like 18, 24, 30, 36, 42, 48 or 60 — capacity in thousands of BTU; divide by 12 for tons. Our Model Number Decoder does this for 13 US brands using each maker's own published key.

Is this a Manual J calculation?

No. It is this site’s planning estimate, built from area, climate, ceiling height, sun, insulation, occupants, windows and doors; it does not follow Manual J’s method. A licensed contractor should run a full Manual J before you buy a central system.

Method & standards

This calculator uses this site’s planning estimate (area, climate zone, ceiling, sun, insulation, occupants, windows and doors), not an ACCA Manual J calculation. For final central-system sizing, a full ANSI/ACCA 2 Manual J is the standard — ACCA.

Updated 6 November 2026